Technical Specification
Documentation
3D Models (STEP)
Technical Specification
- Typ. Dynamic Range Flow Rate (Water): 0 – 14000 µl/min
- Typ. Dynamic Range Pressure (Water): 0 – 500 mbar
- Typ. Dynamic Range Flow Rate (Air): 0 – 35000 µl/min
- Typ. Dynamic Range Pressure (Air): 0 – 140 mbar
- Operating temperature: 0 – 70 °C
- Size: 30 x 15 x 3,8 mm
- Weight: 2 g
- Burst pressure: 1.5 bar
- Power consumption: 50 mW
- Lifetime: 5000 h
- Material in contact with media: PPSU (only one wetted material)
- Media: liquids and gases
- Noise level: below 50 dB
- Internal volume: 30 µl
- Piezo actuators: 2
- Self-priming
The flow rate of the micropumps shows a linear dependency on the back pressure.
At 0 mbar back pressure the maximum flow rate can be achieved and at the maximum back pressure the flow rate is decreased to 0 ml/min. The relation of pressure and flow rate is linear.